+27 64 987 3021 [email protected] Mon-Fri 8:00-17:30 (SAST)
Moving My Fibre Broadband To Another Room

Moving My Fibre Broadband To Another Room

Browse technical resources about ADSS/OPGW cables, 5G fronthaul, data center interconnect, and fiber optic testing.

  • Computer Room Enclosed Cold Aisle System Solution

    Computer Room Enclosed Cold Aisle System Solution

    Cold aisle containment systems use doors at aisle ends, ceiling panels or lids above racks, and structural frames to create enclosed zones where cold supply air flows directly to IT equipment intakes. Without containment, cold supply and hot exhaust air mix throughout the data. Tate's Cold Aisle Containment (CAC) system efficiently captures cold air from the CRAH or CRAC unit via an underfloor plenum, ensuring the I. T equipment is kept at an effective temperature. Designed to your specification, it can be custom configured to fit any white space layout, enabling a precise. Armstrong aisle containment combines flexible design, strategic sourcing, and American manufacturing to deliver solutions that ensure long-term performance in a rapidly evolving digital world. Rittal Aisle Containment Solutions Provide: Our Containment line reduces costs by up to 30% with an ultra-efficient design.

    [PDF Version]
  • Special Use for Grid Cable Tray Computer Room Projects

    Special Use for Grid Cable Tray Computer Room Projects

    This is a fun and easy solution if you have long cables hanging around your standing deskand can't place them elsewhere. You can use rubber, cardboard, or honestly any material that's strong enough to.


  • Cable tray to fire control room

    Cable tray to fire control room

    Install fire barriers within the tray to isolate different fire zones. When cable trays pass through walls or floors, seal openings using fire-rated penetration sealing materials. They seem like separate things, but they need each other to keep buildings safe. We will look at how these two systems team up to make sure. Cable tray installation must comply with specific technical standards to ensure electrical safety, system reliability, and long-term maintainability. This document outlines the key requirements for cable tray layout, installation, and fireproofing in industrial and commercial environments. At slab penetrations, provide 20–30 mm of firestopping and install a fire-support plate at the top. UL Listed Systems Concrete Wall - C-AJ-4056 3 HR F-Rating, 3/4 HR T-Rating Gypsum. en completely installed, without damage either to conductors or structural system use maintain spacing or to keep cables in place when the tray is ect the minimum bend ra-dius for cables as they exit the bottom of the cable tray.

    [PDF Version]
  • Cable trays enter the fire control room

    Cable trays enter the fire control room

    Install fire barriers within the tray to isolate different fire zones. When cable trays pass through walls or floors, seal openings using fire-rated penetration sealing materials. At slab penetrations, provide 20–30 mm of firestopping and install a fire-support plate at the top. For large. Cable tray installation must comply with specific technical standards to ensure electrical safety, system reliability, and long-term maintainability. Use fire barriers, covers, and dividers to contain flame spread, especially at crossings, risers, and penetrations. The following pages address the 2014 National Electrical Code® requirements for cable tray systems as well as design solutions from practical experience.


  • Dehumidification of the hot aisle in the computer room

    Dehumidification of the hot aisle in the computer room

    Install the dehumidifier intake on the return air path (hot aisle side) where moisture content is highest. Position condensate drainage with redundant paths. As computer room air conditioning units (CRACs) were controlled to relatively low supply air temperatures, it was not uncommon for a CRAC unit to dehumidify the room air while at the same time a different CRAC unit could be in humidification mode. Such a humidity-control strategy is like. This article explains practical approaches to air conditioning for computer rooms, focusing on maintaining stable temperatures and humidity, selecting suitable systems, and implementing maintenance practices that minimize downtime and energy use. Operating above 60% RH accelerates corrosion on copper and silver contacts inside servers. Data centers generate heat every second of every day. Servers, storage equipment, network switches, UPS systems, power distribution equipment, and high-density computing racks all produce heat that must be removed continuously.

    [PDF Version]
  • Dimensions of the room s lighting distribution box

    Dimensions of the room s lighting distribution box

    These are the standard rectangular boxes you often see used for single light switches or electrical outlets in US homes. Their dimensions are generally around 2 inches wide by 4 inches tall, with depths varying from 1-1/2 inches to 3-1/2 inches. This guide explains typical wall-mount and floor-standing dimensions, how to read catalog sizes, and how to choose the right enclosure size for your layout. Whether you are installing outlets, switches, lighting fixtures, or junction connections, box size directly affects wire fill capacity, device fit, and installation quality. Crowded boxes can damage wires and pose a fire or shock hazard. It is a device that is a type of distribution board that helps in protecting cables from overload and then damage or accidents. Figure 6: Electric room sizes using the 2023 edition of the NEC are larger in design because clearances listed in Table 110.

    [PDF Version]
  • How to clean fiber optic cables in a computer room price

    How to clean fiber optic cables in a computer room price

    This guide explains practical steps and recommended tools to safely clean fiber optic components in a typical American network setup. Even the smallest dust particle or trace of oil can disrupt signal transmission, cause costly downtime, or permanently damage connectors. In fiber optics, cleanliness isn't optional—it's the difference between peak performance and. The complete solution for precision end-face fiber optic cable cleaning. However, even microscopic dust, oil, or debris on connectors can cause signal loss, increased latency, and network downtime. Prevent. Proper fiber optic cleaning requires specialized tools and techniques.


  • Fiber optic cable bending degree in computer room equipment

    Fiber optic cable bending degree in computer room equipment

    Always keep the fiber optic cable bend radius at least 20 times the cable diameter during installation and 10 times after installation to prevent damage and signal loss. Proper bend radius control ensures the integrity of optical performance and protects the glass. This article provides a practical, installation-focused guide to fiber bend radius, including definitions, standards, common mistakes, and best practices.


  • How much does it cost to build a cold aisle computer room

    How much does it cost to build a cold aisle computer room

    The cost of constructing a cold room can vary significantly based on its size, design, insulation materials, and equipment required. Typically, the average price range for a basic cold room starts around $10,000 and can go as high as $50,000 or more for larger, more complex installations. One of. For customization, extra piping, queries, standby performance cost, etc. On average, the cold storage construction cost per square foot ranges from $130 to $350, making it two to three times. When calculating the cost of cold room, we generally need to understand the actual project use requirements and storage requirements, and understand the size of the cold room (length, width and height), temperature of the cold room, and distribution of the cold room. Add that to the initial investment cost, and potential consulting fees and cooling costs add up quickly. Total yearly investment for enterprise data center cooling systems can easily be in the $100,000s, while. Basic small cold rooms generally cost between £3,000 and £8,000, while medium-sized cold rooms typically range from £3,000 to £15,000.

    [PDF Version]

Need Product Pricing?

Contact us for competitive quotes on any of our fiber optic products

Get a Quote