+27 64 987 3021 [email protected] Mon-Fri 8:00-17:30 (SAST)
Record Your Computer Screen And Audio For Free

Record Your Computer Screen And Audio For Free

Browse technical resources about ADSS/OPGW cables, 5G fronthaul, data center interconnect, and fiber optic testing.

  • How to record the workload of fiber optic cable splicing

    How to record the workload of fiber optic cable splicing

    Use this fiber optic splicing report template to document telecom field work from start to finish. Record customer and work order details, crew roles, and work completed such as butt splice, ring tap, fiber turn, testing, and case re entry. fCONSTRUCTION QUALITY REQUIREMENTS FOR FTTP & SSP Work Orders This document provides Construction Technicians, Construction Managers, FTTP/SSP Vendors, and Inspectors with the essential information to ensure a quality build and to successfully pass an Outside Plant Inspection. With this app. For outside plant work, fusion splicing is almost always the right choice. Mechanical splices are faster for emergency restoration but have higher typical loss (0. 1dB for fusion) and degrade over time in outdoor environments. At Turn-Key. In this comprehensive guide, we detail advanced splicing techniques, explain how data analytics and Business Intelligence drive operational improvements, and explore how field engineers can leverage insights to optimize network performance.

    [PDF Version]
  • Is the audio cable an optical fiber cable

    Is the audio cable an optical fiber cable

    In September 2012, NTT Japan demonstrated a single fiber cable that was able to transfer 1 per second (10 bits/s) over a distance of 50 kilometers. Although larger cables are available, the highest strand-count single-mode fiber cable commonly manufactured is the 864-count, consisting of 36 ribbons each containing 24 strands of fiber. These high fiber count cables are used in, and as distribution cables in and networks.


  • Fiber Optic Cable LED Screen

    Fiber Optic Cable LED Screen

    Discover high-performance LED Screen Cables with active optical fiber technology. Offering ultra-long-distance transmission, anti-electromagnetic interference, and low latency, they ensure smooth, accurate display effects for LED billboards. Optical fiber is to convert electrical signals into optical signals and use transparent glass fibers for transmission. The transparent glass fibers are made of pure quartz and can. Our Fiber Cable are in Single and Multi mode optical fiber cable finished product, which is mainly used for AV, Broadcast and LED Video wall applications. 0 to Fiber Extender, HDMI to Fiber Converters, Cat6 to Fiber Extender, DVI to Fiber, 2K@60Hz, 4K@30Hz DVI to Fiber Extenders, DVI to Fiber Converters, SDI to Fiber Extender and. Optical Fiber (Fiber Optic Cable) For long-distance transmission, fiber optic cables are the best solution.

    [PDF Version]
  • Free quote for SFP optical module 200G

    Free quote for SFP optical module 200G

    How Do I Get A Quote For 200G Optical Transceiver? You can get a quote by contacting our customer service department, which is available 24/7. Get the package format, wavelength and SFP module variety you need, just give us your requirements and we'll take care of the. SULITON has the ability to provide OEM and ODM of dozens of optical modules from 1G to 800G at a price that satisfies you. It is compatible with most switches(CISCO, Huawei, etc) Compared to existing QSFP28, it has fewer optical components, excellent power consumption, and cost performance. We. Superxon 200G QSFP56 LR4 transceiver modules are designed for use in 200 Gigabit Ethernet links on up to 10km of single mode fiber. They are compliant with the QSFP MSA and IEEE 802. Digital diagnostics functions are available via the I2C interface. 200G QSFP56 Optical Transceiver Module is a CZT fiber optic and SFP interconnect product for data center, telecom, and optical networking programs. It is supported by local product imagery. 5 Gbps data rate, thus 200G Ethernet application.

    [PDF Version]
  • Free quote for high-density edge data centers

    Free quote for high-density edge data centers

    ✔ Best-fit data center matches based on your requirements and direct introductions to the right reps. ✔ Tell us your specs (kW, racks, location, bandwidth. ) and get instant ballpark pricing, terms and contacts of providers within hours vs weeks. At EdgeConneX, we're more than a reliable and trusted partner—we are catalysts for innovation, revolutionizing how industries operate with AI-enabled, high-density data centers. By streamlining processes and optimizing resources, our infrastructure powers breakthroughs that enable tomorrow's. Edge data center solutions from Vertiv offer the fastest path to scale Edge capacity. They are proven to accelerate deployment while driving end-to-end simplicity and reduce risk of hidden costs and project delays. *No, you don't pay extra, we are. Resilient, secure edge data centre infrastructure built for mission-critical, latency-sensitive workloads.

    [PDF Version]
  • Fiber optic cable protection pipe in the computer room

    Fiber optic cable protection pipe in the computer room

    PVC Riser Pipe is a lightweight, flame-retardant plastic conduit specifically designed to encompass and shield fiber optic cables. It shields cables from environmental hazards such as wind, rain, UV rays, and physical damage caused by accidental snags or deliberate vandalism. Whether for underground or overground installations, you have a wide choice of cable protection solutions to ensure your power and cable lines are fully protected during repair, retrofitting or constrution work. Either rigid or flexible, made of PE, PP or PVC, sand-proof, waterproof or fireproof. Fiber optic cable carries enormous amounts of data, but the glass or plastic fiber at its core is unforgiving of mechanical stress, moisture infiltration, and improper installation practices. Unlike copper cable, fiber does not tolerate being kinked, crushed, or over-tensioned during a pull. They can be used in all areas of general construction and civil engineering, in road construction and also in the construction of tunnels and tracks.

    [PDF Version]
  • Grounding of the outer sheath of optical cable in the computer room

    Grounding of the outer sheath of optical cable in the computer room

    Follow these steps at each cable entry point and termination location to achieve a compliant, safe ground bond: Identify metallic components. Strip back approximately 6–8 inches of the outer jacket using a cable slitter or ringing tool. Visually identify armor, strength members, or. Fiber optic cable transmits data as light through glass or plastic strands, which means the fiber core itself carries no electrical current and requires no grounding. The critical distinction lies in. Grounding of cable shield or outer sheath at both ends can results in circulating currents that may require cable derating, depending on the cable length and construction. A table is provided by ANSI/IEEE 525 recommending the maximum lengths of single point shield grounding. Operational grounding rules, especially for medium and high-voltage grids, may vary according to each country's regulations. Refer to Table 1 for kit part numbers. Contact your customer service representative to. Armored fiber-optic cable bonding and grounding are simple phases in the installation process but are sometimes misunderstood or omitted. It offers ruggedness and superior crush resistance.

    [PDF Version]
  • Why are server racks in the computer room divided into A and B

    Why are server racks in the computer room divided into A and B

    This arrangement places server racks in alternating rows where equipment fronts face each other to form cold aisles, while the backs create hot aisles. Cold air flows into the front of servers, and hot exhaust air exits through the rear. Server Room (Computer Room) The Server Room is the operational heart of the data center, housing all critical IT equipment. As a core infrastructure component in data centers and telecom rooms, it houses critical devices such as servers, routers, and switches, enabling secure deployment and. A server room is a dedicated space designed to house computer servers, networking devices, and related hardware that manage data and applications.


  • Fiber optic cable bending degree in computer room equipment

    Fiber optic cable bending degree in computer room equipment

    Always keep the fiber optic cable bend radius at least 20 times the cable diameter during installation and 10 times after installation to prevent damage and signal loss. Proper bend radius control ensures the integrity of optical performance and protects the glass. This article provides a practical, installation-focused guide to fiber bend radius, including definitions, standards, common mistakes, and best practices.


  • Function of Computer Optical Modulators

    Function of Computer Optical Modulators

    An optical modulator is a device that tweaks the properties of an optical beam—like its intensity, phase, or polarization—using an electrical signal. These nifty gadgets are the backbone of high-speed data transmission, laser technology, and even some scientific measurements. The beam may be carried over free space, or propagated through an optical waveguide (optical fibre). Each type works best for certain speeds and distances. They also help keep errors low. Performance metrics like. Optical modulators are a foundational building block in fiber-optic communication and laser systems because they provide a controlled, repeatable way to translate electrical information into changes in a light wave.


  • Hot aisle in industrial computer room

    Hot aisle in industrial computer room

    The hot aisle /cold aisle data center layout was originated by IBM in 1992 and it is one of the oldest ways to save energy in the data center. 1 Hot aisle/cold aisle layout involves lining up server racks in alternating rows with cold air intakes – the fronts of servers – facing each other (the. Traditional open aisle data centres use perimeter PAC (precision air conditioning) or CRAC (computer room air conditioning) units to channel cold air up through a raised floor void via grilles positioned in front of the IT cabinets. When implemented. Assuming a computer room is configured in such a way that either is an option, hot aisle containment may be seen as the better option because it has some thermal efficiency and ride-through advantages. However, because every computer room is unique, there is no one definitive solution. To maintain thermal performance, equipment accessibility, and safety, it's essential to follow key spatial guidelines. Maximum Aisle Length: When equipment cabinets form a continuous row.

    [PDF Version]

Fiber Optic & Power-Grid Insights

Need Product Pricing?

Contact us for competitive quotes on any of our fiber optic products

Get a Quote