+27 64 987 3021 [email protected] Mon-Fri 8:00-17:30 (SAST)
Unified Ai Security Platform For Enterprise Protection

Unified Ai Security Platform For Enterprise Protection

Browse technical resources about ADSS/OPGW cables, 5G fronthaul, data center interconnect, and fiber optic testing.

  • Can fire protection cables be run through security cable trays

    Can fire protection cables be run through security cable trays

    Use separate cable trays or conduit for fire alarm cables to prevent interference from power cables or other electrical circuits. Where cables pass through shafts, walls, slabs, or enter electrical panels or cabinets, openings shall be tightly sealed. Segregation of Power and Signal Cables: Power (high-voltage) and signal (low-voltage) cables should be routed separately, using dedicated trays to minimize electromagnetic interference. Tray Type and Material Selection Indoor: Painted steel or galvanized trays. Outdoor: Hot-dip galvanized or. The large number of cable support systems run concealed in cable tunnels behind wall and floor coverings. Electrical lines can ignite themselves due to overheating or a short-circuit or they can be set alight by the external influence of fire or heat.

    [PDF Version]
  • Protection Measures for Primary Distribution Boxes in Engineering

    Protection Measures for Primary Distribution Boxes in Engineering

    Design requirements help you follow important standards like NEC and IEC, which protect you from electrical accidents. A robust waterproof distribution box shields sensitive components from moisture, dust, and mechanical impacts. This guide primarily analyzes structural engineering characteristics. U. Electric System Overview Substations serve as critical nodes connecting generation, transmission, and distribution networks. These rules guide you to use proper labeling, provide safe maintenance access, and reduce risks with the right personal protective equipment. The table below shows why these. Pushbutton Enclosures: These enclosures are available in various shapes and forms including slope tops, consoles, and more. Models. The first digit is our shield against these invaders: IP5X (Level 5): Dust-resistant—keeps out most particles but not completely dust-tight.

    [PDF Version]
  • Relay protection operates at zero-sequence voltage

    Relay protection operates at zero-sequence voltage

    A zero-sequence voltage relay is a protective device designed to detect imbalances in three-phase power systems by measuring the zero-sequence voltage component. Many microprocessor-based relays now offer negative-sequence current elements as a means of detecting mented in nearly all microprocessor-based relays. Why the power system needs to be protected? All current and voltage vectors have 120 degrees phase shifts and a sum of 0. At the time of a fault. broken delta-connected VTs, that monitors zero sequence voltage. Sequence networks and calculations are used to explain the setting of the overvoltage threshold for a single line-to-ground fault. Open COMTRADE Waveform, timing, phasors, cursors.


  • Relay protection wiring pins

    Relay protection wiring pins

    Use Correct Pin Assignments: ISO/DIN 72552 standardizes relay pins. Pin 30 is the common terminal, pins 85 and 86 connect to the relay coil, pin 87 is normally open and pin 87a is normally closed. Understand the Core Concepts: Relay is an electromechanical or solid-state switch. Relays are fundamental components of modern electrical systems in today's electrical world. We use relays generously in automobiles, test and measurement. In this article we'll study the basic rules that will help us to identify relay pinouts and learn regarding how a relay works. This guide covers relay wiring for various pin configurations, including step-by-step instructions, diagrams, and practical tips. Understanding Relay. In the wiring diagrams that are shown in this publication, the type of Allen-Bradley® Guardmaster® device is shown as an example to illustrate the circuit principle.

    [PDF Version]
  • Requirements for laying relay protection cables

    Requirements for laying relay protection cables

    This handbook covers the code of practice in protection circuitry including standard lead and device numbers, mode of connections at terminal strips, colour codes in multicore cables, dos and donts in execution. Also principles of various protective relays and schemes including special protection. Abstract: Information on the concepts of protection of ac transmission lines is presented in this guide. Setting of protection relays to achieve selectivity.


  • Low-power relay protection principle

    Low-power relay protection principle

    Under voltage relays, also known as low voltage relays, work by detecting when the electrical current dips under a set value. They are intended to quickly identify a fault and isolate it so the balance of the system continue to run under normal conditions. The selection and applications of. Combines protection, sensors, control power, and circuit breaker in a single package Typically added to a breaker close circuit to prevent accidental reclosure after a trip. Three fundamental components required for each circuit breaker. To understand the phenomenon of Over Voltages and its classification. Long term cost reduction (TCO) for trainings and maintenance by reduce variety of relays A fast and selective arc fault mitigation for air-insulated LV & MV switchgear and Relion protection and control relays and sensor. A protective relay definition is; a switchgear device used to detect faults & begin the circuit breaker operation to separate the faulty element of the system.

    [PDF Version]
  • Principles for verifying protection settings in relay protection

    Principles for verifying protection settings in relay protection

    The objective of relay protection is to quickly isolate a faulty section from both ends so that the rest of the system can function satisfactorily. The functional requirements of the relay:.


  • Protection of Optical Cables and Power Poles

    Protection of Optical Cables and Power Poles

    The protection procedure is related to the exposure of the line to direct lightning discharges and includes the selection of cable characteristics/installation, use of shield wires, bonding/earthing of the cable shield, installation of surge protective devices (SPD) and. The protection procedure is related to the exposure of the line to direct lightning discharges and includes the selection of cable characteristics/installation, use of shield wires, bonding/earthing of the cable shield, installation of surge protective devices (SPD) and. Optical Cables with OKM metal elements in the structure ( ply protective shell, power components, copper wire for transmitting remote power supply) must be protected against lightning and hazardous effects of electromagnetic power lines and electrified railways AC as required by the LPC 45-136. —. Another type of aerial fiber optic cable combines electrical distribution cables with optical fibers inside the conductors. Metallic barriers and layers are also replaced by.

    [PDF Version]
  • Short lead protection of relay protection

    Short lead protection of relay protection

    The objective of relay protection is to quickly isolate a faulty section from both ends so that the rest of the system can function satisfactorily. The functional requirements of the relay:.


  • Example of Relay Protection Calculation

    Example of Relay Protection Calculation

    Use this Protection Relay Setting Calculator to calculate pickup current, time multiplier settings (TMS), operating time, coordination time interval (CTI), and plug setting multiplier (PSM) using fault current, CT ratio, and IEC 60255 curve parameters. This technical report refers to the electrical protections of all 132kV switchgear. All calculations are based on the available documentation/ information. The protective philosophy is fundamentally grounded on the understanding that faults or abnormal operating. PSM and TMS settings that are Plug Setting Multiplier and Time Multiplier Setting are the settings of a relay used to specify its tripping limits. Plug Setting Multiplier (PSM): The ratio of the fault current to the relay's pickup current, critical for relay operation.

    [PDF Version]

Need Product Pricing?

Contact us for competitive quotes on any of our fiber optic products

Get a Quote